2 resultados para surgical and invasive medical procedures

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-invasive molecular-imaging technologies are playing a key role in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various deceases in vivo. However, it is limited by the availability of vectors with high selectivity to the target and radionuclides with a physical half-life which matches the biological half-life of the observed process. The 68Ge/68Ga radionuclide generator makes the PET-nuclide anywhere available without an on-site cyclotron. Besides the perfect availability 68Ga shows well suited nuclide properties for PET, but it has to be co-ordinated by a chelator to introduce it in a radiopharmaceuticals.rnHowever, the physical half-life of 68Ga (67.7 min) might limit the spectrum of clinical applications of 68Ga-labelled radiodiagnostics. Furthermore, 68Ga-labelled analogues of endoradiotherapeuticals of longer biological half-live such as 90Y- or 177Lu-labeled peptides and proteins cannot be used to determine individual radiation dosimetry directly. rnThus, radionuclide generator systems providing positron emitting daughters of extended physical half-life are of renewed interest. In this context, generator-derived positron emitters with longer physical half-life are needed, such as 72As (T½ = 26 h) from the 72Se/72As generator, or 44Sc (T½ = 3.97 h) from the 44Ti/44Sc generator.rnIn this thesis the implementation of radioactive gallium-68 and scandium-44 for molecular imaging and nuclear medical diagnosis, beginning with chemical separation and purification of 44Ti as a radionuclide mother, investigation of pilot generators with different elution mode, building a prototype generator, development and investigation of post-processing of the generator eluate, its concentration and further purification, the labeling chemistry under different conditions, in vitro and in vivo studies of labeled compounds and, finally, in vivo imaging experiments are described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.